2

TABLE of CONTENTS

PG 2-5 INTRODUCTION

15-17

FINISHING

Warranty

 

Door Removal

General Instructions

 

Glass Removal

General Information

 

Frame/Front Installation

Care of Glass and Plated Parts

 

Accent Glass Installation

Dimensions

 

LK8 Light Installation (Optional)

5-10

VENTING

18

OPERATING INSTRUCTIONS

 

Venting Lengths and Air Terminal Locations

19

MAINTENANCE

 

Vent Installations

 

Typical Vent Installations - Horizontal Termination

19

ADJUSTMENTS

 

Typical Vent Installations - Vertical Termination

 

Minimum Air Terminal Location Clearances

 

Gas Pressure Adjustment

 

Venting Application Flow Chart

 

Venturi Adjustment

10-15

INSTALLATION/FRAMING

 

Flame Characteristics

20

REPLACEMENTS

 

Wall and Ceiling Protection

 

Vertical Installation

 

Replacement Parts

 

Using Flexible Vent Components

 

Flexible Vent Kits

 

Horizontal Air Terminal Installation

 

Terminal Kits

 

Vertical Air Terminal Installation

 

Accessories

Fireplace Vent Connection

Mobile Home Installation

Gas Installation

Electrical Connection

Stand-off Assembly

Nailing Tab Installation

Framing

Clearance to Combustibles

This appliance may be installed as an OEM installation in a manufactured home (USA only) or mobile home and must be installed in accordance with the manufacturers instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 in the United States or in the Mobile Home Standard, CAN/CSA Z240 MH, Series in Canada.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

!WARNING

Do not burn wood or other materials in this fireplace.

Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Supervise young children when they are in the same room as the fireplace.

Clothing or other flammable material should not be placed on or near the fireplace.

Due to high temperatures, the fireplace should be located out of traffic and away from furniture and draperies.

Ensure you have incorporated adequate safety measure to protect infants/toddlers from touching hot surfaces.

Even after the fireplace is out, the glass and/or screen will remain hot for an extended period of time.

Check with your local hearth specialty dealer for safety screens and hearth guards to protect children from hot surfaces. These screens and guards must be fastened to the floor.

Any safety screen or guard removed for servicing must be replaced prior to operating the fireplace.

It is imperative that the control compartment and burner in the fireplace and venting system are kept clean. The fireplace and its venting system

should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. The fireplace area must be kept clear and free from combustible materials, gasoline and other flammable vapours and liquids.

Under no circumstances should this fireplace be modified.

This fireplace must not be connected to a chimney flue pipe serving a separate solid fuel burning appliance.

Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water.

Do not operate the fireplace with the glass door removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person.

Do not strike or slam shut the fireplace glass door.

The glass door must be kept closed while the fireplace is operating to prevent exhaust fumes containing carbon monoxide, from entering into the home. Temperatures of the exhaust escaping through this opening can also cause the surrounding combustible materials to overheat and catch fire.

Only doors / optional fronts certified with the unit are to be installed on the appliance.

W415-0619 / B / 03.03.08

NOTE: Changes, other than editorial, are denoted by a line in the margin.

 

Page 2
Image 2
Napoleon Fireplaces GT8N, Fireplace, GT8P manual Table of Contents

GT8N, Fireplace, GT8P specifications

Napoleon Fireplaces has long been recognized as a leader in the heating industry, and the GT8N and GT8P models embody their commitment to innovation, efficiency, and style. These fireplaces are designed to provide not only warmth but also a striking aesthetic that complements various interior designs.

The GT8N and GT8P are part of Napoleon's renowned series of gas fireplaces, which focus on delivering a superior heating experience while maintaining ease of use. One of the standout features of these models is their impressive thermal efficiency, which helps to reduce energy costs while providing consistent heat output. With an energy-efficient design, the GT8N and GT8P ensure that homes remain cozy during the harshest of winters.

Both models offer a range of customizable options to suit individual preferences. The GT8N features a traditional design with classic styling, while the GT8P is more contemporary, boasting a sleek, modern look. The extensive selection of finishing materials, including various trim options and media placements, allows homeowners to customize their fireplace to seamlessly fit into their living spaces.

One of the most innovative technologies featured in the GT8N and GT8P is the advanced heat distribution system. This allows for optimal circulation of warm air throughout the room, ensuring that heat is evenly dispersed and preventing cold spots. The fireplaces are equipped with variable-speed fans that can be adjusted according to the desired heat output, providing flexibility for different situations.

Safety is a top priority in the design of the GT8N and GT8P. Both models come equipped with protective features, such as a built-in safety system that detects any irregularities in operation. Additionally, the fireplaces utilize a sealed combustion system, drawing air from outside for combustion, which minimizes the impact on indoor air quality.

Another key characteristic of the GT8N and GT8P is their ease of installation and maintenance. These fireplaces are designed to be easily integrated into existing layouts, providing versatility in home design. Moreover, the straightforward maintenance schedule, combined with high-quality materials, ensures long-lasting performance and reliability.

In summary, the Napoleon Fireplaces GT8N and GT8P represent the ideal blend of style, efficiency, and advanced technology. Whether looking for a traditional or contemporary aesthetic, these fireplaces meet the diverse needs of homeowners while providing exceptional warmth and comfort. With features that prioritize both functionality and safety, Napoleon continues to set the standard in the world of gas fireplaces.