18
BLOWER REPLACEMENT
The Napoleon PARK AVENUE comes equipped with a heat circulating blower. The blower is
Drywall dust will penetrate into the blower bearings, caus- ing irreparable damage. Care must be taken to prevent drywall dust from coming into contact with the blower or its compartment. Any damage resulting from this condi- tion is not covered by the warranty policy.
1.Turn off the power to the fireplace.
2. Turn off the gas valve. | figure 37 |
|
BLOWER
MOUNTING
PLATE
REMOVE 4 SCREWS
3.Remove the glass door, logs, rear log supports, brick panels, air deflector, burner assy, panel support, panel sup- port bracket.
4.The blower mounting plate can now be removed. Remove the four screws that secure the plate to the firebox base.
5.The blower is secured to the firebox. Disconnect the wire connectors before attempting to remove the blower from the firebox.
6.Remove the two screws securing the blower and lift through blower access opening.
figure 38
Note: When
REMOVE 2 SCREWS |
NIGHT LIGHT REPLACEMENT
Your PARK AVENUE comes equipped with our “Night Light”. The light has been
If in the event the lamp or lens needs to be replaced, follow the instructions below.
Unplug the wireharness
/transformer from the junction box inside the fireplace.
figure 39
LENSE
FRAME
SCREWS
FIREBOX TOP
figure 40
figure 41
GASKET
LENSE
FRAME
Remove the four screws that secure the lens frame.
This frame retains the glass lens. The lamp can now be accessed.
Note: Do not handle the lamp (bulb) with bare fingers, protect with a clean dry cloth.
The lamp will pull straight out of the socket. Replace with Wolf Steel parts only, as lamp and lens are special “high temperature” products.
When
The firebox must be sealed.
Over tightening the screws could break the lens.
“Light Leakage” from the upper area may be observed.
The holes in the lamp housing are necessary for
ventilation and must not be covered.