26
OPERATING INSTRUCTIONS
When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condition caused by the curing of paints and lubricants used in the manufactur- ing process and will not occur again. Simply open a window to sufficiently ventilate the room.
After extended periods of
slight odour for a few hours. This is caused by dust particles in the heat exchanger burning off. Open a window to sufficiently ventilate the room.
Purge all gas lines with the glass door of the fireplace
open. Assure that a continuous gas flow is at the
burner before closing the door.
FOR YOUR SAFETY READ BEFORE
a.this fireplace is equipped with a pilot which must be lit by hand while following these instructions exactly.
b.before operating smell all around the fireplace area for gas and next to the floor because some gas is heavier than air and will settle on the floor.
c.use only your hand to turn the gas control knob / manual
d.do not use this fireplace if any part has been under water. immediately call a qualified service technician to inspect the fireplace and replace any part of the control system and any gas control which has been under water.
WHAT TO DO IF YOU SMELL GAS
•Do not touch any electric switch.
•Do not use any phone in your building.
•If you cannot reach your gas supplier, call the fire department.
•Turn off all gas to the fireplace.
•Do not try to light any appliance.
•Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s instructions.
figure 65
gas knob
LIGHTING INSTRUCTIONS
Warning: if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Initial lighting of the pilot and main burners must be done with the glass door off.
Do not connect valve or wall switch to electricity. See insta llation instructions.
When lighting and
1.STOP! read the safety information on the operating label.
2.Turn off all electric power to the fireplace.
3.Turn the gas knob clockwise to off.
4.Wait 5 minutes to clear out any gas. If you smell gas, including near the floor, STOP! Follow “B” on the op erating label. If you don’t smell gas, go to the next step.
5.If the fireplace is equipped with a flame adjustment valve, turn clockwise to off.
6.Find pilot located infront of the back log on the right side.
7.Turn gas knob
8.This unit is equipped with an
Depress and hold gas knob . Keep knob fully de pressed for one minute, then release. If pilot does not continue to burn repeat steps 3 through 7.
9.With pilot lit, turn gas knob
10.If equipped with flame adjustment valve, push and turn knob to high.
11.If equipped with remote
12.Turn on all electric power to the fireplace.
figure 66
SOLENOID PILOT
ON/OFF
KNOB
TO TURN OFF GAS
1.Turn off all electric power to the fireplace if service is to be performed.
2.For a complete
control knob slightly and turnclockwise to off. Do not force.
3.For a temporary
gas knob clockwiseto pilot.