GAS INSTALLATION | 13 |
Read the section on opening the door in "Finishing" prior to proceeding to prevent damaging the unit.
Bring the gas line to the stove through either the opening in the pedestal back or through the floor directly beneath the pedestal base.
Install rigid black pipe, or 1/2" type L copper tubing with a shutoff valve to the stove.
Seal and tighten the gas line securely to the flex connector supplied.
DO NOT KINK FLEXIBLE CONNECTOR.
Mark the appropriate boxes on the rating plate label to indi- cate the model type depending on the installation (direct vent or
CERTIFIED UNDER: CSA |
|
|
|
|
| |||||||||
BURNER KIT: |
|
|
|
|
|
|
|
|
| |||||
HOMOLOGUE SELON LES NORMES: CSA |
|
| ||||||||||||
TION. CET APPAREIL DOIT ETRE INSTALLE EN UTILISANT UN ENSEMBLE DU BRULEUR: |
|
| ||||||||||||
|
|
|
|
| ALTITUDE/ELEVATION |
|
|
|
|
| ||||
|
|
|
|
|
|
| ||||||||
|
|
| 30,000 BTU/h |
|
| INPUT/ALIMENTATION |
|
| 26,000 BTU/h |
|
|
| ||
|
|
| 18,000 BTU/h |
| REDUCEDINPUT/ALIMENTATIONREDUITE |
| 15,000 BTU/h |
|
|
| ||||
|
|
|
|
| ||||||||||
|
|
| 22,500 BTU/h |
| OUTPUT (CDVS280/GDS28)RENDEMENT |
| 19,500 BTU/h | |||||||
|
|
| 24,000 BTU/h |
| OUTPUT (CS280/GS28) RENDEMENT |
| 20,800 BTU/h | |||||||
#37 |
|
| ORIFICE/INJECTEUR |
| #53 |
|
|
|
|
| ||||
|
|
|
|
|
| DIRECTVENTMODEL |
|
|
|
|
|
|
|
|
|
|
| ‘B’VENTMODEL |
|
|
|
| |||||||
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
FIGURE28
MODEL GDS28 ONLY: Attach the two leads from the on/ off switch to terminals 1 and 3 located on the gas valve.
FIGURE 29 | OL |
|
|
HI | O | F | |
|
|
| O |
|
| N | F |
TOLIP
TOLIP
Do not connect either the wall switch, thermostat or gas valve to electricity (110 volts).
MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG) / 10 INCHES W.C.(LP)
PRESSION AU COLLECTEUR: 3.5" D'UNE COLONNE D'EAU(GN)
10" D'UNE COLONNE D'EAU (PG)
MIN SUPPLY PRESSURE: 4.5" W.C.(NG) / 11" W.C. (LP)
PRESSIOND'ALIMENTATIONMIN:4.5"D'UNECOLONNED'EAU (GN)
11" D'UNE COLONNE D'EAU (PG)
MAX. SUPPLY PRESSURE: 7" W.C. (NG) / 13" W.C. (LP)
PRESSIOND'ALIMENTATIONMAX:7"D'UNECOLONNED'EAU (GN)
13" D'UNE COLONNE D'EAU (PG)
FOR USE WITH GLASS DOORS CERTIFIED WITH THIS UNIT ONLY.
UTILISER AVEC LES PORTES VITREES HOMOLOGUEES SEULEMENTAVECCETTEUNITE.
WARNING:DONOTADDANYMATERIALTOTHEAPPLIANCE, WHICHWILLCOMEINCONTACTWITHTHEFLAMES,OTHER THANTHATSUPPLIEDBYTHEMANUFACTURERWITHTHEAP- PLIANCE.
AVERTISSEMENT: N'AJOUTEZ PAS A CET APPAREIL AUCUN MATERIAU DEVANT ENTRER EN CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT.
MINIMUMCLEARANCETOCOMBUSTIBLEMATERIAL/ DEGAGEMENTSMINIMAUXDESMATERIAUXCOMBUSTIBLES:
A | 7" | D 17½" |
B | 2" | E 6¼" |
C | 1" | F 9½" |
20"TOCEILINGFROMSTOVETOP 20"ENTRELEDESSUSDUFOYERETLEPLAFOND ELECTRICAL RATING / CLASS.: 115V 1.5AMP 60HZ
MODEL CS280/GS28 APPROVED FOR BEDROOM, &
BEDSITTINGROOMINSTALLATION. HOMOLOGUE POUR IN- STALLATION DANS UNE CHAMBRE A COUCHER, & UN STUDIO.
STEADY STATE EFFICIENCY (NG): 80% FAN OFF / 82%
FAN ON
STEADY STATE EFFICIENCY (LP): 80% FAN OFF / 83%
FAN ON
EFFICACITE CONSTANTE (GN): 80% VENT. ARRETE 82%VENT.FONCTIONNE
EFFICACITECONSTANTE(GP): 80%VENTILATEURARRETE 83% VENTILATEUR FONCTIONNE STEADY STATE EFFICIENCY APPLIES TO CANADA ONLY /
L'EFFICACITECONSTANTES'APPLIQUENTSEULEMENTAU CANADA.
AFUE (NG/LP) (GN/GP): 66% / 68%
THISAPPLIANCEMUSTBEINSTALLEDUSINGANADAPTER
NOT FOR USE WITH SOLID FUEL
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE
AVEC CET APPAREIL
MODEL CDVS280/GDS28 APPROVED FOR BEDROOM, BATH-
ROOM & BEDSITTING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANU- FACTURED HOME INSTALLATIONS, SITES AND COMMUNI- TIES,ANSI/NFPA501A.
HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE SALLE DE BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI SON IN- STALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE DE MAISONS MOBILES EQUIPEES AU GAZ, EN VIGUEUR AU CANADA OU AUX
STEADY STATE EFFICIENCY (NG):75% FAN OFF / 78% FAN ON
STEADYSTATEEFFICIENCY(LP):75% FAN OFF / 79% FAN ON
EFFICACITE CONSTANTE (GN): 75% VENT. ARRETE
78% VENT. FONCTIONNE
EFFICACITE CONSTANTE (GP): 75% VENTILATEUR ARRETE 79%VENTILATEURFONCTIONNE STEADY STATE EFFICIENCY APPLIES TO CANADA ONLY /
L'EFFICACITE CONSTANTE S'APPLIQUENT SEULEMENT AU CANADA.
AFUE (NG/LP) (GN/GP): 64% / 65%
MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS ARE 25 INCHES AND 20 FEET RESPECTIVELY. LES LONGUEURS HORIZONTALES MINIMALE ET MAXIMALE SONT 25 POUCES ET 20 PIEDS RESPECTIVEMENT.
THE APPLIANCE MUST BE VENTED USING THE APPROPRI- ATE NAPOLEON VENT KITS. SEE OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLA- TION AND RESEALING IS NECESSARY AFTER SERVICING THE
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPRE A NAPOLEON. REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR L'EVACUATION PRECISE. IL EST IMPORTANT DE BIEN REINSTALLER ET RESCELLER L'EVENT APRES AVOIR AS- SURE LE MAINTIEN DU SYSTEME DE PRISE D'AIR.
WOLF STEEL LTD
BARRIE, ONTARIO CANADA
MADE IN CANADA / FABRIQUE AU CANADA
SERIALNUMBER GDS28
NO.DESERIE
Check for gas leaks by brushing on a soap and water solu-
tion. DO NOT USE OPEN FLAME.
For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient location. Route a double strand of solid core millivolt wire from the gas stove to the wall switch / millivolt ther- mostat. The recommended maximum lead length de-
pends on the wire size: | WIRE SIZE | |
MAX. LENGTH |
|
|
14 | gauge | 100 feet |
16 | gauge | 60 feet |
18 | gauge | 40 feet |
DIRECT VENT MODEL GDS28: Disconnect the exist- ing wires from terminals 1 and 3 (from the on/off switch) and replace with the leads from the wall switch/millivolt thermostat.