18 ADJUSTMENTS
INLET PRESSURE
TAP
MANIFOLD TAP
FIGURE 36
OL
|
| O |
| N | F |
HI | O | F |
| IP | |
|
| |
|
| TOL |
TOLIP
PILOT SCREW
PILOT BURNER ADJUSTMENT
Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow.
VENTURI ADJUSTMENT
Remove the 2 screws securing the control panel plate. To access the venturi, remove the air housing cover plate, held on with 2 screws. Take care not to damage the gasket. Natural gas and propane models have air shutters set fully open. Closing the air shutter will cause a more yellow flame, but can lead to carboning. The flame may not appear yel- low immediately; allow 15 to 30 minutes for the final flame colour to be established. After making adjustments re- place the gasket and cover plate.
THERMOPILE |
|
FLAME MUST ENVELOP | THERMO- |
COUPLE | |
UPPER 3/8" TO 1/2" OF | FIGURE 38 a |
THERMOCOUPLE & |
|
THERMOPILE | AIR HOUSING |
FIGURE 37 | COVER PLATE |
FIGURE39
Air shutter adjustment must only be done by a qualified gas installer!