22 SYMPTOM

22 SYMPTOM

PROBLEM

TEST SOLUTION

 

 

 

 

Main burner goes out; pilot goes out.

REFER TO "MAIN BURNER GOES OUT; PILOT STAYS ON"

 

Vent re-circulating

-

check joint seals and installation.

 

(MODEL GDS28 ONLY)

 

 

 

Thermocouple shorting or

- loosen and tighten thermocouple

faulty.

-

clean thermocouple and valve connection.

 

 

-

replace thermocouple.

 

 

-

replace valve.

Exhaust

fumes

Fireplace is spilling.

- check all seals.

smelled in

room,

 

 

headaches.

 

 

 

Carbon is being de- posited on glass, logs or combustion chamber surfaces.

Air shutter has become

-

ensure air shutter opening is free of lint or other obstruc-

blocked

tions.

 

 

 

Flame is impinging on the

-

check that the logs are correctly positioned.

logs or combustion chamber.

-

open air shutter to increase the primary air.

 

-

check the input rate: check the manifold pressure and orifice

size as specified by the rating plate values.

- check that the door gasketing is not broken or missing and that the seal is tight.

- check that both vent liners are free of holes and well sealed at all joints.

- check that minimum rise per foot has been adhered to for any horizontal venting.

- when heating with propane, ensure that the screen frame is secured as far to the back of the fireplace as possible.

Door sticking.

Dirt / dust adheres to the

 

hinges; is heated and burns

 

causing sticking.

- lift door from its hinges. Lubricate with high-temp dry graph- ite only. Replace.

NOTE: Due to the high temperatures that the hinges experi- ence, wet lubricants such as oil and WD40 will cause the hinge to seize and are therefore not suitable.

MODELGDS28ONLY:

Blockage in vent.

-

remove blockage. In really cold conditions, ice buildup may

Main burner flame is

 

occur on the terminal and should be removed as required.

 

a blue, lazy, transpar-

Incorrect installation.

-

refer to Figure 20 to ensure correct location of storm collars

ent flame.

 

 

 

 

White / grey film

Sulphur from fuel is being de-

-

clean the glass with a recommended gas fireplace glass

forms.

posited on glass, logs or com-

cleaner. DO NOT CLEAN GLASS WHEN HOT.

 

bustion chamber surfaces.

If deposits are not cleaned off regularly, the glass may be-

 

 

come permanently marked.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 