ON/OFF

10 STOVE VENT CONNECTION

1.Attach the adjustable pipe to the last section of rigid piping. Secure with screws and seal.

2.Install the 4" aluminium flexible liner to the stove. Se- cure with 3 screws and flat washers. Seal the joint and screw holes using the high temperature sealant provided.

3.Run a bead of high temperature sealant around the inside of the air intake collar. Pull the adjustable pipe a minimum 2" into the air intake collar.

Ensure that the sealant is not visible on the exte- rior pipes once installation is completed. An op- tional decorative brass band is available for this use. (Standard with a GD175 kit). In the event that the venting must be disassembled, care must be taken to reseal the venting.

FIGURE 21

#8x1/2"

SELF DRILLING SCREWS

2" OVERLAP

HI-TEMP SEALANT

ON/OFF

SWITCH

VARIABLE

COMBUSTION AIRSPEED SWITCH COVER PLATES

& GASKETS

MOBILE HOME INSTALLATION

In Canada, mobile home installation may be vented hori- zontally or vertically. In the United States, it may only be installed vertically. See "Vertical Venting" or "Horizontal Air Terminal Installation" for installation.

The fireplace is equipped with two 5/16" diameter holes located near each corner of the base. For mobile home installations, the fireplace must be fastened in place. Use #10 screws, inserted through the holes in the base to se- cure. It is recommended that the fireplace be secured in all installations.

8"

COMBUSTION AIRSPEED SWITCH COVER PLATES 11½"