Chapter 8 Programmable Function Interfaces (PFI)
© National Instruments Corporation 8-5 NI 6124/6154 User Manual
• AO Start Trigger (ao/StartTrigger)
• Counter n Source
• Counter n Gate
• Counter n Internal Output
•Frequency Output
•PXI_STAR
•RTSI<0..7>
•(NI 6124 Only) Analog Comparison Event
•(NI 6124 Only) Change Detection Event
•(NI 6124 Only) DI Sample Clock* (di/SampleClock)
•(NI 6124 Only) DO Sample Clock* (do/SampleClock)
Note Signals with a * are inverted before being driven to a terminal; that is, these signals
are active low.
Using PFI Terminals as Static Digital Inputs and OutputsYou can configure PFI terminals to be static digital input or output
terminals:
•NI 6124 Devices—Each PFI can be individually configured as a static
digital input or a static digital output. When a terminal is used as a
static digital input or output, it is called P1.x or P2.x. On the I/O
connector, each terminal is labeled PFIx/P1.x or PFI x/P2.x.
In addition, NI 6124 devices have eight lines of bidirectional DIO
signals.
•NI 6154 Devices— When a terminal is used as a static digital input or
output, it is called P0.x or P1.x. On the I/O connector, each terminal is
labeled PFI x/P0.x or PFI x/P1.x.