© National Instruments Corporation 6-1 NI 6124/6154 User Manual
6
Digital I/ORefer to one of the following sections, depending on your device:
•Digital I/O for Non-Isolated Devices—NI 6124 devices have eight
lines of bidirectional DIO lines on Port 0, and 16 PFI signals that can
function as static DIO lines.
•Digital I/O for Isolated Devices—NI 6154 devices have six
bank-isolated digital inputs and four bank-isolated digital outputs.
Digital I/O for Non-Isolated Devices
(NI 6124 Only) NI 6124 devices contain eight lines of bidirectional DIO lines
on Port0 . In addition, The NI 6124 has 16 PFI lines that can function as
static DIO lines.
These S Series devices support the following DIO features on Port0:
• Eight lines of DIO
• Direction and function of each terminal individually controllable
• Static digital input and output
• High-speed digital waveform generation
• High-speed digital waveform acquisition
• DI change detection trigger/interrupt