Chapter 5 Performing Machine Vision Tasks
© National Instruments Corporation 5-5 IMAQ Vision for LabWindows/CVI User Manual
b. If you use imaqFindTransformRects(), specify two
rectangular objects, each containing one separate, straight
boundary of the object, as shown in Figure5-3. The boundari es
cannot be parallel. The regions must be large enough to include
the boundaries in all the images you want to inspect.
Figure 5-3. Locating Coordinate System Axes with Two Search Areas
2. Use the options parameter to choose the options you need to locate the
edges on the object, the coordinate system axis direction, and the
results that you want to overlay onto the image. Set the options
parameter to NULL to use the default options.
3. Choose the mode for the function. To build a coordinate transform for
the first time, set the mode parameter to IMAQ_FIND_REFERENCE.
Toupdate the coordinate transform in subsequent images, set this
mode to IMAQ_UPDATE_TRANSFORM.
1 Primary Search Area
2 Secondary Search Area
3 Origin of the Coordinate System
4 Measurement Area
1
3
2
4
1
3
2
4
b.a.