Chapter 3 VXI-MXI-2 Configuration andI nstallation
© National Instruments Corporation 3-11 PCI-MXI-2 for Linux
Figure 3-6. SMB CLK10 Settingsa. Drive Inverted External CLK SMB (Default)
S2 Off On
S3 Out In
S4 Off On
NON-INVERTED
S5
SMB CLK10 Direction
SMB CLK10 Output Polarity (Effective only when S3 is set to “OUT”)
INVERTED
NON-INVERTEDINVERTED
NON-INVERTEDINVERTED
NON-INVERTEDINVERTED
b. Drive Non-Inverted External CLK SMB
c. Receive External CLK SMB
S2 Off On
S3 Out In
S4 Off On
S5
SMB CLK10 Direction
SMB CLK10 Output Polarity (Effective only when S3 is set to “OUT”)
S2 Off On
S3 Out In
S4 Off On
S5
SMB CLK10 Direction
50 Termination for SMB CLK10 (Effective only when S3 is set to “IN”)
SMB CLK10 Output Polarity (Effective only when S3 is set to “OUT”)
d. Receive External CLK SMB with 50 Termination
50 Termination for External Trigger Input
50 Termination for SMB CLK10 (Effective only when S3 is set to “IN”)
S2 Off On 50 Termination for External Trigger Input
S3 Out In
S4 Off On
S5
SMB CLK10 Direction
50 Termination for SMB CLK10 (Effective only when S3 is set to “IN”)
SMB CLK10 Output Polarity (Effective only when S3 is set to “OUT”)
50 Termination for External Trigger Input
50 Termination for SMB CLK10 (Effective only when S3 is set to “IN”)
50 Termination for External Trigger Input