Chapter 4 Analog Input
NI 6232/6233 User Manual 4-24 ni.com
A counter on your device internally generates ai/SampleClock unless you
select some external source. ai/StartTrigger starts this counter and either
software or hardware can stop it when a finite acquisition completes. When
using an internally generated ai/SampleClock, you also can specify a
configurable delay from ai/StartTrigger to the first ai/SampleClock pulse.
By default, this delay is set to two ticks of the ai/SampleClockTimebase
signal. When using an externally generated ai/SampleClock, you must
ensure the clock signal is consistent with respect to the timing requirements
of ai/ConvertClock. Failure to do so may result in ai/SampleClock pulses
that are masked off and acquisitions with erratic sampling intervals. Refer
to the AI Convert Clock Signal section for more information on the timing
requirements between ai/ConvertClock and ai/SampleClock.
Figure 4-11 shows the relationship of ai/SampleClock to ai/StartTrigger.
Figure 4-11. ai/SampleClock and ai/StartTrigger

AI Sample Clock Timebase Signal

You can route any of the following signals to be the AI Sample Clock
Timebase (ai/SampleClockTimebase) signal:
20 MHz Timebase
100 kHz Timebase
•PXI_CLK10
•RTSI <0..7>
Input PFI <0..5>
•PXI_STAR
ai/SampleClockTimebase is not available as an output on the I/O connector.
ai/SampleClockTimebase is divided down to provide one of the possible
ai/SampleClockTimebase
ai/StartTrigger
ai/SampleClock
Delay
From
Start
Trigger