Chapter 5 Analog Output
NI 6232/6233 User Manual 5-8 ni.com
deasserted and another edge of the sample clock is received, as shown in
Figure 5-5.
Figure 5-5. ao/PauseTrigger with Other Signal Source
Using a Digital Source
To use ao/PauseTrigger, specify a source and a polarity. The source can be
one of the following signals:
Input PFI <0..5>
•RTSI<0..7>
•PXI_STAR
The source also can be one of several other internal signals on your DAQ
device. Refer to Device Routing in MAX in the NI-DAQmx Help or the
LabVIEW 8.x Help for more information.
You also can specify whether the samples are paused when ao/PauseTrigger
is at a logic high or low level.

Routing AO Pause Trigger Signal to an Output

Terminal
You can route ao/PauseTrigger out to RTSI <0..7>.

AO Sample Clock Signal

Use the AO Sample Clock (ao/SampleClock) signal to initiate AO samples.
Each sample updates the outputs of all of the DACs. You can specify an
internal or external source for ao/SampleClock. You also can specify
whether the DAC update begins on the rising edge or falling edge of
ao/SampleClock.
Pause Trigger
Sample Clock