Chapter 7 Counters
NI 6232/6233 User Manual 7-26 ni.com
Nyquist frequency of the system. Figure 7-28 shows an example of pulse
generation for ETS; the delay from the trigger to the pulse increases after
each subsequent Gate active edge.
Figure 7-28. Pulse Generation for ETS
For information on connecting counter signals, refer to the Default Counter
Terminals section.

Counter Timing Signals

M Series devices feature the following counter timing signals.
Counter n Source
Counter n Gate
Counter n Aux
Counter n A
Counter n B
Counter n Z
Counter n Up_Down
Counter n HW Arm
Counter n Internal Output
Counter n TC
•Frequency Output
In this section, n refers to either Counter 0 or 1. For example, Counter n
Source refers to two signals—Counter 0 Source (the source input to
Counter 0) and Counter 1 Source (the source input to Counter 1).
OUT
D1 D2 = D1 + ΔDD3 = D1 + 2ΔD
GATE