Chapter 4 Analog Input
NI 6232/6233 User Manual 4-26 ni.com

Using an External Source

Use one of the following external signals as the source of ai/ConvertClock:
Input PFI <0..5>
•RTSI <0..7>
•PXI_STAR

Routing AI Convert Clock Signal to an Output

Terminal
You can route ai/ConvertClock (as an active low signal) out to any output
PFI <6..9> or RTSI <0..7> terminal.
PFI <0..5> terminals are fixed inputs. PFI <6..9> terminals are fixed
outputs.

Using a Delay from Sample Clock to Convert Clock

When using an internally generated ai/ConvertClock, you also can specify
a configurable delay from ai/SampleClock to the first ai/ConvertClock
pulse within the sample. By default, this delay is three ticks of
ai/ConvertClockTimebase.
Figure 4-12 shows the relationship of ai/SampleClock to ai/ConvertClock.
Figure 4-12. ai/SampleClock and ai/ConvertClock
ai/ConvertClockTimebase
ai/SampleClock
ai/ConvertClock
Delay
From
Sample
Clock
Convert
Period