© National Instruments Corporation 29 NI WLS/ENET-9163 Carrier User Guide and Specifications
EnvironmentalThe NI WLS/ENET-9163 carrier is intended for indoor use only. For
outdoor use, mount the system in a suitably rated enclosure.
Operating temperature
(IEC-60068-2-1 and IEC-60068-2-2).... 0 to 55 °C
Storage temperature
(IEC-60068-2-1 and IEC-60068-2-2).... –10 to 70 °C
Ingress protection...................................IP 30
Operating humidity
(IEC-60068-2-56)...................................10 to 90% RH, noncondensing
Storage humidity (IEC-60068-2-56)...... 5 to 90% RH, noncondensing
Maximum altitude..................................2,000 m
Pollution Degree (IEC 60664)............... 2
Shock and VibrationTo meet these specifications, you must panel mount the
NIW LS/ENET-9163 carrier and affix ferrules to the ends of the terminal
lines.
Operational shock.................................. 30 g peak, half-sine, 11 ms pulse
(Tested in accordance with
IEC-60068-2-27. Test profile
developed in accordance with
MIL-PRF-28800F.)
Random vibration
Operating........................................ 5 to 500 Hz, 0.3 grms
Nonoperating.................................. 5 to 500 Hz, 2.4 grms
(Tested in accordance
with IEC-60068-2-64.
Nonoperating test profile
exceeds the requirements of
MIL-PRF-28800F, Class 3.)