AppendixB CablingRequirements for PXI-8460 Low-Speed CAN
PXI-846xand NI-CAN for Windows NT B-8 ni.com
3. Insertthe replacement resistors into the empty sockets.
4. Refer to Install the Hardware, in Chapter 2, Installation and
Configuration, to complete the hardware installation.
Cabling Example
Figure B-7 showsan example of a cable to connect two low-speed CAN
devices.For the internal power configuration, the V+ connection is
requiredfor the low-speed transceiver to operate as specified in the Philips
data sheet.
FigureB-7. CablingExample
9-Pin
D-Sub
9-Pin
D-Sub
CAN_H
CAN_L
GND
V+
V+
V
V
5-Pin
Combicon
5-Pin
Combicon
Pin7Pin4 Pin7 Pin4
Pin2 Pin2
Pin5 Pin3
Pin9 Pin5
Pin3 Pin1
Pin2Pin2
Pin5Pin3
Pin9Pin5
Pin3Pin1
Power
Connector