AppendixC CablingRequirements for PXI-8461 High-Speed CAN
©NationalInstruments Corporation C-7 PXI-846xand NI-CAN for Windows NT
Cabling ExampleFigure C-6 showsan example of a cable to connect two CAN devices. For
the internalpower configuration, no V+ connection is required.
FigureC-6. CablingExample
9-Pin
D-Sub
9-Pin
D-Sub
CAN_H
CAN_L
Shield
V+
V+
V–
V–
5-Pin
Combicon
5-Pin
Combicon
Pin7Pin4 Pin7 Pin4
Pin2 Pin2
Pin5 Pin3
Pin9 Pin5
Pin3 Pin1
Pin2Pin2
Pin5Pin3
Pin9Pin5
Pin3Pin1
120Ω120 Ω
Power