Chapter 3 Theory of Operation
© National Instruments Corporation 3-15 SCXI-1121 User Manual
Analog Output CircuitryFigure 3-6 shows the SCXI-1121 analog output circuitry.
Figure 3-6.  Analog Output Circuitry
The SCXI-1121 output circuitry consists of a buffered-output multiplexer 
and channel-select hardware. The channel-select hardware consists of a 
two-bit counter, MUXCOUNTER. This counter is needed when the board 
is operating in the Multiplexed-Output Mode. The counter output is sent to 
the multiplexer address pins to determine which of the four channels is to 
be connected to MCH0. In the Single-Channel Read mode, the 
MUXCOUNTER is loaded with the desired channel number. In the 
Scanning mode, the counter is loaded with the first channel to be read. 
During the scan, the counter is clocked by SCANCLK from the data 
acquisition board, or TRIG0 from the SCXIbus, depending on the state of 
the CLKSELECT bit in the Configuration Register. During scanning 
operations, the MUXCOUNTER is reloaded with the channel value stored 
AB0
Switch
Buffer MCH0+
Output 
Mux
Channel 0
Channel 1
Channel 2
Channel 3 MCH0–
MCH1+From
Channel 1
From
Channel 2
MCH1–
From
Channel 3
MCH2–
MCH2+
MCH3+
MCH3–
DTEMP MCH4+
MCH4–
MTEMP
Analog
Reference
SCXIbus
Rear Signal Connector
Output
Stage
Control
Output Stage and
Hardware Scan Control