NEC 4210W Tint Gain Data Function, Sharpness Gain Data Function, Contrast Gain Data Function

Models: 4210W

1 60
Download 60 pages 53.27 Kb
Page 51
Image 51

10.TINT Gain Data Function

The external control equipment changes the TINT gain data of the PlasmaSync 4210W.

Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: TINT Gain Flag

05H

DATA02: TINT Gain

EAH: -22

FFH: -01

00H: 0

01H: +01

16H: +22

ACK

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00:

USER PICTURE Gain Flag

01H

DATA01:

TINT Gain Flag

05H

11.SHARPNESS Gain Data Function

The external control equipment changes the SHARPNESS gain data of the PlasmaSync 4210W.

Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: SHARPNESS Gain Flag

06H

DATA02: SHARPNESS Gain

F0H: -16

FFH: -01

00H: 0

01H: +01

10H:+16

ACK

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00:

USER PICTURE Gain Flag

01H

DATA01:

SHARPNESS Gain Flag

06H

12.CONTRAST Gain Data Function

The external control equipment changes the CONTRAST gain data of the PlasmaSync 4210W.

Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: CONTRAST Gain Flag

07H

DATA02: CONTRAST Gain

00H : 0

 

 

 

 

34H: +52

ACK

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00:

USER PICTURE Gain Flag

01H

DATA01:

CONTRAST Gain Flag

07H