04.VOLUME Gain Data Function

The external control equipment changes the VOLUME gain data of the PlasmaSync 4210W.

Transmission Data

 

 

 

DFH 80H 60H 7FH 03H

DATA00

DATA01

DATA02 CKS

DATA00: USER SOUND Gain Flag 05H

 

 

DATA01: VOLUME Gain Flag

01H

 

 

DATA02: VOLUME Gain

 

 

 

 

00H: Step 0

 

0AH: Step 10 (Default)

2AH: Step 42

ACK

 

 

 

7FH 60H 80H 7FH 02H DATA00

DATA01

CKS

DATA00: USER SOUND Gain Flag

05H

 

 

DATA01: VOLUME Gain Flag

01H

 

 

05.SCREEN MODE Select Function

The external control equipment switches the screen mode of the PlasmaSync 4210W.

Transmission Data

 

 

 

 

 

DFH 80H

60H

51H

01H

01H DATA00

CKS

DATA00

02H : STADIUM

 

 

 

 

03H

: ZOOM

 

 

 

 

04H

: NORMAL

 

 

 

 

05H

: FULL

 

 

 

 

ACK

 

 

 

 

 

 

7FH 60H

80H

51H

01H

DATA00

CKS

 

DATA00

02H : STADIUM

 

 

 

 

03H

: ZOOM

 

 

 

 

04H

: NORMAL

 

 

 

 

05H

: FULL

 

 

 

 

06.AUDIO Mute On Function

The external control equipment switches on AUDIO Mute of the PlasmaSync 4210W.

Transmission Data

9FH 80H 60H 3EH 00H CKS

ACK

3FH 60H 80H 3EH 00H CKS

07.AUDIO Mute Off Function

The external control equipment switches off AUDIO Mute of the PlasmaSync 4210W.

Transmission Data

9FH 80H 60H 3FH 00H CKS

ACK

3FH 60H 80H 3FH 00H CKS

42