CHAPTER 4 CIRCUIT CARD INFORMATION
List of Required Circuit Card
NEAX2000 IVS2 Q-SIG System Manual
ND-70923 (E), Issue 1.0 Page 61
NOTE 1: Set the groove on the switch to the desired position.NOTE 2: When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit card.NOTE 3: Set SW0-1 and SW0-2 as follows:NOTE 4: When the PBX is a clock source office, set the SW0-1 and SW0-2 on all the DTI cardsmounted in PIM0 to “OFF”.NOTE 5: Mount the DTI card which receives a source clock signal into PIM0.
CONDITIONS
DTI0 DTI1 DTI2 DTI3 DTI4
REMARKS
SW
0-1 SW
0-2 SW
0-1 SW
0-2 SW
0-1 SW
0-2 SW
0-1 SW
0-2 SW
0-1 SW
0-2
When one DTI is
provided. ONOFF––––––––
MP card will receive the
clock signal from DTI0 at its
PLO0 input.
When more than
one DTI is pro-
vided. ON OFF OFF ON OFF OFF OFF OFF OFF OFF
MP card will receive the
clock signal from DTI0 at its
PLO0 input, under normal
conditions.
Should a clock failure occur
with DTI0, MP card will auto-
matically switch to the PLO1
input which gets clock from
DTI1.