NEC PlasmaSync 3300 user manual Terminal Board, External Control, A DIP Switches, C Video

Models: PlasmaSync 3300

1 31
Download 31 pages 49.53 Kb
Page 7
Image 7
Terminal Board

Terminal Board

0

B

5 4 3 2 1

10

9

8

7

6

15

14

13

12

 

11

5 4 3 2 1

10

9

8

7

6

15

14

13

12

 

11

OPEN

ON

￿“

1 2 3 4 5 6 7 8

SHORT

OPEN

ON

￿“

1 2 3 4 5 6 7 8

SHORT

A

C

5

0 EXTERNAL CONTROL

EXTERNAL CONTROL IN (mini D-SUB 15 PIN).....This terminal is used when

power ON/OFF, input selection, AUDIO MUTE and PICTURE MUTE are operated externally (by external control). See also page 41 for external con- trol port pin assignments.

NOTE: Select EXT. CONTROL ON by setting pin No. 7 of DIP SW 1 to ON when operating the monitor by external control.

NOTE: When in the EXT. CONTROL mode, the following operations of

the supplied remote control are not possible: Power control ON/ OFF, Input selection, and Audio mute ON/OFF.

EXTERNAL CONTROL OUT (mini D-SUB 15 PIN)..... Connect to a second moni-

tor' s EXTERNAL CONTROL input to relay the signal input at the EXTER-

NAL CONTROL IN.

The EXTERNAL CONTROL THROUGH OUT terminal is used to connect several monitors together (up to 50) and allows all of the monitors to be controlled by one external control. No. 7 pin (EXT. CONTROL) of DIP SW 1 must be set to the ON position on all of the monitors.

A DIP Switches

DIP SW 1.....This DIP switch sets various conditions of the monitor. See

pages 17 and 18 for more details.

DIP SW 2.....This DIP switch sets Sync. Control and the Intelligent Power

Manager. Set all eight pins to the OFF positions during normal operation. See pages 19 and 20 for more details.

B REMOTE IN/OUT..... When the supplied remote control is used in the

wired condition, connect the supplied remote cable to the REMOTE IN termi- nal. The REMOTE OUT terminal is used to connect several monitors to- gether and allows all of the monitors to be controlled by one remote control.

NOTE: Up to 50 monitors can be connected in the serial connection.

C VIDEO 1

VIDEO 1 IN (BNC type).....Connect to a video output of the external source.

S-VIDEO 1 IN.....Connect the S-video source with an S-connector output

here.

THROUGH OUT (BNC type).....Connect to a second monitor' s video input to

relay the video signal input at VIDEO 1 IN.

THROUGH OUT (S-VIDEO).....Connect to a second monitor' s S-connector

input to relay the video signal input at S-VIDEO 1 IN.

75 Ω/HIGH Impedance Select Switch.....Set to "75 Ω" during normal opera-

tion. In multiple connections using VIDEO 1 IN and THROUGH OUT ter- minals, set to "HIGH" on all but the last monitor. Set to "75 Ω" on the last monitor only.

AUDIO R IN..... Connect the stereo right channel audio output here.

AUDIO L IN (MONO).....Connect the mono audio or stereo left channel au-

dio output here.

AUDIO R THROUGH OUT.....Connect to a second monitor' s audio right

channel input.

AUDIO L THROUGH OUT .....Connect to a second monitor' s audio left chan-

nel input.

6