FS518T.Manual.FINAL 5/19/00 12:55 PM Page 40
Category 5 Cable
Category 5 distributed cable that meets
•20 ft (6 m) between the hub and the patch panel (if used)
•295 ft (90 m) from the wiring closet to the wall outlet
•10 ft (3 m) from the wall outlet to the desktop device
The patch panel and other connecting hardware must meet the requirements for
100 Mbps operation (Category 5). Only 0.5 inch (1.5 cm) of untwist in the wire pair is allowed at any termination point.
Category 5 Cable Specifications
Ensure that the fiber cable is crossed over to guarantee link.
Table
Table C-1. Electrical Requirements of Category 5 Cable
Specification | Category 5 Cable Requirements |
|
|
Number of pairs | Four |
|
|
Impedance | 100 Ω ± 15% |
|
|
Mutual capacitance at 1 KHz | ≤ 5.6 nF per 100 m |
|
|
Maximum attenuation (dB per 100 m, at 20° C) | at 4 MHz: 8.2 |
| at 31 MHz: 11.7 |
| at 100 MHz: 22.0 |
|
|
NEXT loss (dB minimum) | at 16 MHz: 44 |
| at 31 MHz: 39 |
| at 100 MHz: 32 |
|
|
cabling guidelines |