Chapter 4. Installation | 21
GS752TXS Smart Switch Hardware Installation Guide
Step 1: Preparing the Site
Before you install the switch, ensure the operating environment meets the site requirements in
the following table.
Step 2: Installing the Switch
The GS752TXS Smart Switch can be used on a flat surface or mounted in a standard
network equipment rack.

Installing the Switch on a Flat Surface

The switch ships with four self-adhesive rubber footpads. Stick one rubber footpad on each of
the four concave spaces on the bottom of the switch. The rubber footpads cushion the switch
against shock and vibrations. They also provide ventilation space between stacked switches.

Installing the Switch in a Rack

To install the switch in a rack, you need the 19-inch rackmount kit supplied with the switch.
1. Attach the supplied mounting brackets to the side of the switch.
2. Insert the screws provided in the rackmount kit through each bracket and into the bracket
mounting holes in the switch.
3. Tighten the screws with a #1 Phillips screwdriver to secure each bracket.
Characteristics Requirements
Mounting Desktop installations - Provide a flat table or shelf surface.
Rackmount installations - Use a 19-inch (48.3-centimeter) EIA standard equipment rack that
is grounded and physically secure. The rackmount kit supplied with the switch is also required.
Access Locate the switch in a position that allows you to access the front-panel RJ-45 ports, view the
front-panel LEDs, and access the power connector.
Power source Provide a power connection cord. Power specifications for the switch are shown in Appendix A.
Ensure the AC outlet is not controlled by a wall switch, which can accidentally turn off power to
the outlet and the switch.
Environmental Tempera ture - Install the switch in a dry area, with ambient temperature between 0 and 40ºC
(32ºF and 104ºF). Keep the switch away from heat sources such as direct sunlight, warm air
exhausts, hot-air vents, and heaters.
Operating humidity - The installation location should have a maximum relative humidity of
90%, non-condensing.
Venti lation - Do not restrict airflow by covering or obstructing air inlets on the sides of the
switch. Keep at least 2 inches (5.08 centimeters) free on all sides for cooling. Be sure there is
adequate airflow in the room or wiring closet where the switch is installed.
Operating conditions - Keep the switch at least 6 ft. (1.83 meters) away from nearest source
of electromagnetic noise, such as a photocopy machine.