New Buck Corporation DV23ZC manual Introduction

Models: DV23ZC

1 33
Download 33 pages 10.86 Kb
Page 5
Image 5
INTRODUCTION

INTRODUCTION

This instruction manual will help you obtain a safe, efficient, dependable installation for your appliance and vent system. Please read and understand these instructions before beginning your installation.

The model DV23ZC is a sealed combustion, air circulating gas appliance designed for residential and mobile home applications. The appliance must be installed with Dura-Vent GS vent system that is routed to outside atmosphere. It is also listed for bedroom installations.

This appliance is designed to operate on natural or propane gas. A millivolt gas control valve with piezo ignition system provides safe, efficient operation. No external electrical power is required to operate the gas valve and burner. 120VAC is required to operate the room air fan.

This appliance complies with National Safety Standards and is tested and listed by (ITS) Intertek Testing Services (Warnock Hersey) to ANSI Z21.88-2002 and CSA 2.33-2002ISA CAN/CGA-2.17-M91- Appliance for use at high altitudes. Installation must conform to local codes. In the absence of local codes, installation must comply with the current National Fuel Gas Code, ANSI Z223.1/NFPA54.. (In Canada, installation must comply with the current CAN-1B149installation code.)

Approved for manufactured (Mobile) home installation. For mobile housing, Title 24 CFR, Part 3280 or when such a standard is not applicable, the standard for manufactured home installation, ANSI / NCBS A225.1 or standard for gas equipped recreation vehicles and mobile housing, CSA Z240.4.

SPECIFICATIONS - MODEL DV23ZC

 

GAS:

NAT.

L.P.

HIGH FIRE

22,000 BTU

22,000 BTU

LOW FIRE

14,000 BTU

17,600 BTU

GAS INLET PRESSURE:

NAT.

L.P.

MAX. INPUT

10.5" W.C.

14.0" W.C.

MIN. INPUT

*5.0" W.C.

10.5" W.C.

*5.0" W.C. is minimum inlet gas supply pressure for the purpose of input adjustment.

MANIFOLD PRESSURE:

NAT.

L.P.

 

3.5" W.C.

10.0" W.C.

STEADY STATE EFFICIENCY:

 

 

NATURAL GAS

77.10%

 

L.P. GAS

77.10%

FLUE VENT

4" INNER, 6" OUTER; DURA-VENT MODEL GS

SAFETY

AGA CERTIFIED PILOT GENERATOR, MILLIVOLT

 

SYSTEM ACTIVATED WITH SWITCH OR THERMOSTAT.

3

Page 5
Image 5
New Buck Corporation DV23ZC manual Introduction