TO CHANGE THE PANEL FILTER - Cont.

SERVICE INSTRUCTIONS

TO CHANGE THE PANEL FILTER - Cont.

1.Park the sweeper on a smooth level surface, Turn the key switch to the “OFF” position and engage the wheel lock.

2.Disconnect the Battery Connector, which is located next to the seat.

3.Raise the Battery compartment cover and engage the safety latch.

4.Remove the rear cover.

5.Locate and remove the four wing nuts that hold the filter manifold assembly in place over the filter.

6.Disconnect the shaker motor leads and the Vac fan leads and lift the Vac Fan/Manifold assembly off thedust filter.

7.Remove and replace the dust filter.

8.Reinstall the cleaned filter and assemble the Vac Fan/Manifold Assembly to the filter.

9.Connect the shaker motor leads and the Vac fan leads.

10.Install the four Wing Nuts and tighten enough to lightly compress the gasket on the filter.

11.Reinstall the Rear cover and lower the Battery Compartment cover.

12.Reconnect the Battery and return the Sweeper to service.

FLAP SERVICE INSTRUCTIONS

The Flaps are very important to the sweeping process. Inspect the Flaps Daily and replace any flap that shows signs of wear or deterioration. The drive wheel and side flaps are adjustable and should be adjusted so there is a recommended 1/16" to 1/8" gap between the floor and the bottom edge of the flaps. The adjustable flaps have slotted mounting holes to facilitate adjustment. The Recycling flap is also an adjustable flap and should be adjusted so the flap touches the broom. The adjustment bolt is located inside the left side broom chamber door. All other flaps require no adjustment and should be replaced when worn or damaged.

FLAP SERVICE INSTRUCTIONS WARNING

Turn Key Off Before removing Battery Connector. Disconnecting the Battery with the key switch on will produce

sparks and Could cause an Explosion.

TO ADJUST THE DRIVE WHEEL AND SIDE FLAPS WARNING

Always park on a level surface, turn key off, and engage wheel lock before working on the machine to keep it

from creeping or rolling.

TO ADJUST THE DRIVE WHEEL AND SIDE FLAPS

1.Park Sweeper on a smooth level surface. Turn the key switch to the “OFF” position and engage the wheel lock.

2.Disconnect the Battery Connector located next to the seat.

3.Loosen the Flap retaining screws and adjust the flap to clear the floor and leave a 1/16" to 1/8" Gap.

4.Tighten Flap retaining screws while holding flap in position.

5.Reconnect the Battery Connector.

C0477b WARNING

Turn Key Off Before removing Battery Connector. Disconnecting the Battery with the key switch on will produce

sparks and Could cause an Explosion.

 

RECYCLING FLAP

 

FLAP ADJUSTMENT

 

SCREW

C0477b

FIGURE 13

TO ADJUST THE RECYCLING FLAP WARNING

Always park on a level surface, turn key off, and engage wheel lock before working on the machine to keep it from creeping or rolling.

TO ADJUST THE RECYCLING FLAP

1.Park Sweeper on a smooth level surface. Turn the key switch to the “OFF” position and engage the wheel lock.

2.Disconnect the Battery Connector located next to the seat.

3.Open the left side broom door and locate the recycling flap adjustment screw (See Figure 13)

4.Loosen the adjustment screw and turn the flap upwards so the flap touches the ends of the broom bristles.

5.Tighten the adjustment screw while holding the flap in place.

6.Close and Latch the left side broom door Reconnect the Battery.