Safety precautions and warnings
GROUNDING INSTRUCTIONS
This product must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for electrical current to reduce the risk of electric shock. This product is equipped with a cord having an
DANGER - - Improper connection of the
Ground Fault Circuit Interrupter Protection
This pressure washer may be equipped with a Ground Fault Circuit Interrupter (GFCI) on the power cord. This device provides additional protection from the risk of electrical shock. Should replacement of the plug or cord become necessary, use only identical replacement parts that include GFCI protection.
EXTENSION CORDS
Use only
WARNING - - To reduce the risk of electrocution, keep all connections dry and off the ground. Do not touch the plug with wet hands.
2.3 Operation
(also see Sec. 3.0, Operating instructions)
High or low pressure (Sec. 4.2)
Generally speaking, high pressure loosens soil, and low pressure moves it.
Attack the „dirtiest“ areas first, with high pressure. Then complete the task with a combination of high and low pressure as appropriate.
Technique (also see Sec. 4.4)
Generally, it’s best not to allow areas still being cleaned to dry before you’ve finished. This is espe- cially true if you’re using detergent. To remove something like chewing gum, use high pressure and „undercut“ it. To gain „reach“ (ie. for the eaves of the house), use high pressure. Experimentation will produce the ideal setting for your cleaning task.
2.4 Safety devices on the machine
Bypass/Overpressure relief
The high pressure side of the pump is equipped with a combination bypass and safety valve. This valve recirculates water back to the low pressure side of the pump when the spray handle is closed or the nozzle is blocked. The bypass/safety valve also ensures that the pump pressure will never exceed the working pressure by more than 300 psi (well within the design strength of the pump). At this pressure, the pump automatically switches from high pressure to bypass mode. The bypass/safety valve also relieves pump pressure when the ma- chine is stopped.
Motor overload protection
The electric motor features overload protection. If an overload occurs (caused by excessive pressure, improper extension cord, or defect), the motor will stop.
5