MACHINE CONTROLS
American-Lincoln 91 WS

MACHINE CONTROLS

 

 

 

 

 

 

 

 

 

 

 

 

 

GAS/LP POWERED MACHINE CONTROLS

 

MAIN BROOM

BATTERY

CHOKE

KEY

 

START

 

 

 

HOUR

LOW

VOLT

 

 

 

 

OIL

LEVER

CONTROL

SWITCH

BUTTON

 

METER

METER

 

LIGHT

 

 

 

 

 

 

 

 

 

 

 

 

MAIN

 

 

 

 

 

 

 

 

 

 

 

 

BROOM

 

 

 

 

 

 

 

 

 

 

 

 

FLOAT

 

 

CHOKE

OFF ON

START

 

 

 

 

 

 

 

12

14

 

 

 

LOW OIL

 

SWEEP

10

16

HOURS

 

 

 

BATTERY

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0

0

0

0

 

 

UP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CB-1

CB-2

FILTER SHAKER

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CIRCUIT

 

 

 

 

FILTER

 

 

 

 

BREAKERS

 

 

 

SHAKER

 

 

 

 

 

FWD./REV.

 

 

SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

MAIN BROOM

 

CONTROL

 

 

 

 

 

 

 

 

HANDLE

 

 

 

 

SIDE BROOM

 

 

ADJUSTMENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIFT CONTROL

 

 

 

 

 

 

 

 

 

 

 

 

C-0601

 

 

 

 

 

 

 

 

 

 

 

C0601

 

 

 

FIGURE 4

 

 

 

 

 

 

START BUTTON (Gas/LP Only)

The start button is located on the right side of the console next to the key switch. The start button is a momen- tary push button switch that energizes the electric starter motor when pushed. The key switch must be turned on before using the start button to start the engine.

WARNING

Do not hold the start button for more than 15 seconds at a time. Allowing the starter motor to run for more than 15

seconds at a time may cause permanent damage to the starter motor.

To start the engine, push and hold the switch until the engine starts.

BATTERY VOLT METER (Gas/LP Only)

The battery volt meter is used to monitor the charging system on GAS/LP Powered machines.

The meter indicates the voltage of the battery. A properly charged battery will indicate approximately 13.8 volts. A reading of less than 12 volts could be an indication of a charging system fault.

CHOKE CONTROL (Gas/LP Only)

The choke control is located on the console. The choke governs the air/fuel mixture during the combustion cycle of the engine operation. The choke should be pulled out while starting the engine and then gradually pushed back in after the engine warms up.

LOW OIL LIGHT (Gas/LP Only)

The low oil light is located on the console. The low oil light is part of a protection feature for the engine. When the oil level drops below a safe level the engine shuts off and illuminates the light to advise the operator of the low oil level. When this occurs check the oil level in the engine and add oil as necessary. The oil level must be full before the engine will start.

FILTER SHAKER SWITCH

The filter shaker switch is a two position rocker switch that is located on the console. When the filter shaker switch is set to the “ON” position the filter shaker will operate automatically for approximately 20 seconds after the key switch is turned off. The “OFF” position disables the automatic shake cycle which would normally occur after turning the key switch off.