| *NOTES | |
|
| MAXIMUM |
| 1. | Subtract 3.5 ft. for each additional 3" 90 degree elbow. | |
| APPLICATION | DIRECT VENT, DUAL | 2. | Two45degreeelbowsareequivalenttoone90degreeelbow. | ||
| PIPE LENGTH (ft.)* | 3. | One short radius elbow is equivalent to two long radius | |||
|
| |||||
|
|
|
|
|
| elbows. |
| PVC,CPVC or ABS | Inlet/Outlet |
| |||
| 4. | Donotincludeterminationelbowsincalculationofventlength. | ||||
| SCH. 40 Pipe Size | 3" |
| 3" | 5. | This table is applicable for elevations from sea level to 4000 |
| Model M3RL 060 | 50 |
| 50 |
| ft. Forhigherelevations,decreaseventpipelengthsby8%per |
|
|
| 1000 ft. of altitude. | |||
| Model M3RL 080 | 50 |
| 50 |
| |
|
| 6. | Only the above pipe materials are approved for use with these | |||
|
|
|
|
|
| condensingfurnaces. |
|
|
|
|
|
|
|
Table 6. Vent Table
| VENT TERMINAL | AIR SUPPLY INLET | AREA WHERE TERMINAL IS NOT PERMITTED | |
|
|
|
|
|
|
| Canadian Installations1 |
| US Installations2 |
A = | Clearance above grade, veranda, porch, | 12 inches (30 cm) |
| 12 inches (30 cm) |
| deck, or balcony |
|
|
|
|
|
|
| |
B = | Clearance to window or door that may be | 6 inches (15 cm) for appliances ≤ 10,000 | 6 inches (15 cm) for appliances ≤ 10,000 | |
| opened | Btuh (3 kW), 12 inches (30 cm) for | Btuh (3 kW), 9 inches (23 cm) for | |
|
| appliances > 10,000 Btuh (3 kW) and ≤ | appliances > 10,000 Btuh (3 kW) and ≤ | |
|
| 100,00 Btuh (30 kW), 36 inches (91 cm) for | 50,000 Btuh (15 kW), 12 inches (30 cm) for | |
|
| appliances >100,00 Btuh (30 kW) | appliances > 50,000 Btuh (15 kW) | |
|
|
|
|
|
C = | Clearance to permanently closed window | * |
| * |
D = | Vertical clearance to ventilated soffit |
|
|
|
| located above the terminal within a | * |
| * |
| horizontal distance of 2 feet (61 cm) from |
| ||
|
|
|
| |
| the center line of the terminal |
|
|
|
E = | Clearance to unventilated soffit | * |
| * |
F = | Clearance to outside corner | * |
| * |
G = | Clearance to inside corner | * |
| * |
H = | Clearance to each side of center line | 3 feet (91 cm) within a height 15 feet | * | |
| extended above meter/regulator assembly | above the meter/regulator assembly | ||
|
| |||
I = | Clearance to service regulator vent outlet | 3 feet (1.83 m) |
| * |
J = | Clearance to nonmechanical air supply inlet | 6 inches (15 cm) for appliances ≤ 10,000 | 6 inches (15 cm) for appliances ≤ 10,000 | |
| to building or the combustion air inlet to any | Btuh (3 kW), 12 inches (30 cm) for | Btuh (3 kW), 9 inches (23 cm) for | |
| other appliance | appliances > 10,000 Btuh (3 kW) and ≤ | appliances > 10,000 Btuh (3 kW) and ≤ | |
|
| 100,00 Btuh (30 kW), 36 inches (91 cm) for | 50,000 Btuh (15 kW), 12 inches (30 cm) for | |
|
| appliances >100,00 Btuh (30 kW) | appliances > 50,000 Btuh (15 kW) | |
|
|
|
|
|
K = | Clearance to a mechanical air supply inlet | 6 feet (1.83 m) |
| 3 feet (91 cm) above if within 10 feet (3 m) |
|
|
|
| horizontally |
|
|
|
|
|
L = | Clearance above paved sidewalk or paved | 7 feet (2.13 m) † |
| * |
| driveway located on public property |
|
| |
|
|
|
| |
|
|
|
|
|
M = | Clearance under veranda, porch deck, or | 12 inches (30 cm) ‡ |
| * |
| balcony |
|
| |
|
|
|
|
1In accordance with the current CSA B149.1 Natural Gas and Propane Installation Code
2In accordance with the current ANSI Z223.1 / NFPA 54 National Fuel Gas Code
†A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.
‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
*For clearances not specified in ANSI Z223.1 / NFPA 54 or CSA B149.1, the following statement shall be included:
“Clearance in accordance with local installation codes, and the requirements of the gas supplier and the manufacturer’s installation instructions.”
Figure 15. Vent Termination Clearances for Direct Vent Furnaces
15