Using the Model 5625HD EtherSpeed Switch Module
4-2 206208-A
Preliminary StepsIf you suspect problems with a newly installed Model 5625HD switch module,
start troubleshooting by checking the following items:
• Check all power cable connections and power sources.
• Check network cable connections to be sure connectors are properly seated.
• Make sure the cables are the correct type, with correctly wired connectors.
• Check the LEDs for indication of link status.
Previous Module Configuration IncompatibilitySymptom: A module in a powered-on chassis fails to start up.
The slot the module occupies in the System 500xBH/BHC chassis may have had a
different module type installed in it previously.
The Model 5625HD switch module keeps the configuration of an identical
replacement module. If the replacement is not a Model 5625HD switch module,
the module needs to be reconfigured after it has been replaced. Follow the
procedure described in “Installing the Switch Module” on page3-6.
To check for possible incompatibility in module type:
1. Connect a SpeedView managemen t station to the MCP port on the
switch, using either the direct c onnection or the modem conn ection.
This procedure is described in Using SpeedView 4.0 for Windows and Release
Notes for SpeedView 4.1.
2. Select the Map menu.
If this module is displayed with all ports disabled, t he MCP module is not able
to manage this module because there is no stored configuration information
about the module. You must enable the ports and download the new
configuration to the MCP module.
After you download the new configuration, you are prompted to reset the
switch.