Using the Model 5625HD EtherSpeed Switch Module
4-4 206208-A
Port Connection ProblemsSymptom: The LED on an Ethernet port is off.
If an LED does not light when traffic is present, there may be a port connection
problem.
To resolve the problem:
1. Verify whether or not the port is enabled , using SpeedView or the CLI.
a. From the Map window in SpeedView, choose Switch and then choose
Configure.
When the configuration information has been downloaded to the
management station, check the port state. The port state should be either
enabled or disabled.
b. From the Map window, choose Statistics.
When the statistics information has been downloaded to the management
station, check the port state. If the port state is Down, the port is receiving
no link signal or it is disabled.
c. From a configuration terminal con nected to the serial port on the
switch, access the CLI.
Use the show port command and specify the module number and port
number for the suspected port. When the port information is displayed,
verify that port_state is up and SPTstate is forwarding.
2. Verify that the cable is correctly connected.
Disconnect and reseat the cable at the Model 5625HD switch module port and
at the patch panel or punchdown block. Check the port LED for a change in
status.