D Logs summary

178 MiLLennium Command Descriptions Manual

RGEB

Format: Message ID = 32 Message byte count = 32 + (obs x 44)

Field # Data Bytes Format Units Offset
1 Sync 3 char 0
(header) Checksum 1 char 3
Message ID 4 integer 4
Message byte count 4 integer 8
2Week number 4 integer weeks 12
3Seconds of week 8 double seconds 16
4Number of observations (obs) 4 integer 24
5Receiver self-test status 4 integer 28
6 PRN 4 integer 32
7Pseudorange 8 double metres 36
8StdDev pseudorange 4 float metres 44
9Carrier phase - accumulated Doppler range, cycles 8 double 48
10 StdDev - accumulated Doppler range, cycles 4 float 56
11 Doppler frequency 4 float Hz 60
12 C/N04float dB-Hz 64
13 Locktime 4 float seconds 68
14 Tracking status 4 integer 72
15... Next PRN offset = 32 + (obs x 44)