2-6 IN9 32X/IN9 32X -MAX
[All ON]: All the LED lights on without any flashing effect.
[MODE 1 ~ MODE 7]: All the LED lights on with the flashing effect by one of these modes.
Temperature Monitoring
Click <Enter> key to enter its submenu:
μGuru Utility v1.00C
ABIT EQ
Temperature Monitoring
Reading Shutdown
Enable
Shutdown
Temp.
Beep
Enable
Beep
Temp.
(*)CPU Temperature 41°C/105°F (*) 85°/185°F (*) 75°C/167°F
(*)System Temperature 27°C/80°F ( ) 65°°C/149°F (*) 55°C/131°F
(*)PWM Phase1 Temperature 40°C/104°F ( ) 135°°C/275°F (*) 125°C/257°F
(*)PWM Phase2 Temperature 40°C/104°F ( ) 135°°C/275°F (*) 125°C/257°F
(*)PWM Phase3 Temperature 40°C/104°F ( ) 135°°C/275°F (*) 125°C/257°F
(*)PWM Phase4 Temperature 38°C/100°F ( ) 135°°C/275°F (*) 125°C/257°F
(*)PWM Phase5 Temperature 39°C/102°F ( ) 135°°C/275°F (*) 125°C/257°F
(*)PWM Average Current 54 A
(*)PWM Peak Current 54 A
:Move Enter:Select +/-/PU/PD:Value F10:Save ESC:Exit
CPU, System, PWM Phase1~5 Temperature/PWM Current
These items display the temperature of CPU, System, and Power Module. Both the average and
peak current of PWM will be displayed as well.
- Shutdown Enable
Use <Space> key to enable system shutdown function. If the CPU/System/PWM’s temperature
exceeds the shutdown temperature limit, the system will shutdown automatically.
- Shutdown Temp.
This items sets the temperature that will shutdown the system automatically in order to prevent
system overheating.
- Beep Enable
Use <Space> key to enable warning beeps function. Once the system has detected that the
CPU/System/PWM’s temperature exceeded the beep temperature limit, warning beeps will
sound.
- Beep Temp.
This item selects the warning temperature limit.
The shutdown temperature must be set above the warning temperature.