NOTE: Eachnumericandgraphicdisplayrepresentsauniquepieceofinforma- tion. It is imperative that you understand the formats, ranges, and values of the informationrepresentedtoavoidanypossiblemisunderstandingthatcouldresult inerror. TheInformationalDisplaysaredescribedindetailasthevariousoperating modestheyappearinarepresentedthroughoutthismanual.

AUDIBLEALARMLEDWarningLight

A red LED Warning Light will light and a Speaker icon will appear when the Audible Alarm emits a tone. They will turn off when the Alarm is acknowledged, and will not activate if the Audible is Set OFF (a user setting).

When warning situations activate the Alarm, the unit will emit a continuous tone for 10 seconds, or until the situation is corrected, or it is acknowledged by the user pressing the Left (Advance) button for 2 seconds. If acknowledged by the user and the situation corrected, the Alarm will sound again upon reentry into the warning situation, or entry into another type of warning situation.

A single short beep (which cannot be disabled) is emitted for the following -

After the Diagnostic countdown, if everything is okay.

If the unit automatically returns to Surface Mode from Simulator Mode.

Upon completion of a Hot Swap battery change with calculations saved.

Change from Delayed to Full Violation 5 minutes after the dive.

14