N2
O2
ATR
Fig. 17 - Set Mode 1
N2
O2
ATR
Fig. 18 - Set Mode 2
Settings are divided into 2 categories. Set Mode #1 includes several settings that you would change more often and Set Mode #2 includes those items not likely to change once you set them. Set Mode 2 can be accessed by first entering settings in Set Mode 1, or by bypassing Set Mode 1.
Settings can be made one after the other, or you can access a specific item that you want to set, bypassing others. Set points can be advanced by scrolling (press/hold) or one increment at a time (press/release < 2 seconds)
Set Mode Access TimingWhile in Surface Mode, press Both buttons simultaneously and hold -
•after 2 seconds, SET: 1 appears (Fig. 17)
•after 2 more seconds, SET: 2 appears (Fig. 18)
•Access is gained by releasing the buttons during the 2 second window in which SET: 1 or SET: 2 appears. then pressing the Left (Advance) button.
•If the buttons are held longer, and SET 1 and 2 are both bypassed, the unit will go to Simulator (Demo) Mode which is described on page 75.
•While in the Set Mode, if neither button is pressed during a 2 minute period, the unit will revert to Surface Mode.
24