DelayedViolationMode#2 (Fig. 62)
The Pro Plus 2 cannot calculate decompression times for Stop Depths much greater than 60 feet (18 meters) and offers no indication of how much time spent underwater would result in the need for a greater Stop Depth.
If the Decompression obligation requires a Ceiling Stop Depth between 60 feet (18 meters) and 70 feet (21 meters), the Tissue Loading Bar Graph will flash. Total Ascent Time will still be displayed.
You must ascend to just deeper than, and stay as close as possible to, 60 feet (18 meters) without causing the Total Ascent Time display to flash. When the Required Stop Depth indicates 50 FT/ 15 M, etc., you can ascend to those depths and continue decompressing.
DelayedViolationMode#3 (Fig. 63)
If you descend deeper than 330 feet (99.9 meters), the accumulated Tissue Loading Bar Graph segments will flash, and the Current Depth and Max Depth displays will only indicate 3 dashes ( - -
N2 DECO
FEET
O2 | PSI |
0 5 10 20 30 40 50
ATR
Fig. 62 - Delayed Violation #2
N2
FEET
MAX
O2 |
|
| PSI |
0 | 5 | 10 | 20 |
| ATR |
|
|
Fig. 63 - Delayed Violation #3
59