RESET FEATURE
This dive computer is configured with a RESET feature that allows data to be cleared, including Nitrogen and Oxygen calculations, FO2 set point, Log Mode entries, and Download data.
WARNING: Reset after a dive and subsequent use for a repetitive dive conducted by the same diver could result in serious injury to or death.
RESET PROCEDURE
•While in SURFACE MODE (new activation period or greater than a 10 minute post dive surface interval), press the Left (Advance) button one (1) time to access PLAN MODE.
•While 30 feet (or 9 meters) is displayed in the PLAN MODE, press and hold Both buttons until SET 2 appears, then release the buttons.
•Press and release the Left (Advance) button to display the first 2 digits of the assigned KEY CODE, flashing as 00.
•Press and release the Right (Select) button to increase the digits to 01.
•Press and release the Left (Advance) button again to display the second 2 digits of the KEY CODE, flashing as 00.
•Press and release the Right (Select) button to increase the digits to 01.
•Press and release the Left (Advance) button to complete the RESET operation and turn the unit OFF.