•Voltage level is checked upon activation and every 10 minutes during operation.
•When 75 % of the Rated Power has been consumed, only the lower bar of the Indicator will be displayed and the full icon will flash (Fig. 9) once per second as a warning that the Battery is to be replaced prior to con- ducting any further dives.
•Upon decreasing to a voltage level that will no longer sustain proper operation, the Battery Indicator will flash 5 times followed by shutdown of the unit.
•If a Low Battery Condition exists when the unit is manu- ally activated (by pressing the button), the graphic bAT and the Battery Indicator will appear flashing for 5 seconds followed by shutdown of the unit.
•If the button is not pressed to activate the unit prior to a dive (e.g., the unit activated automatically by immersion in water), and a Low Battery Condition exists, the Battery Indicator will appear flashing as a warning upon descent past 4 feet (1.2 meters). No other information will be displayed and the unit will not enter Dive Mode.
N2
O2 | PSI |
ATR
17