Oki MSM83C154S manual ALE Signal Width, Address Setup Time, To ALE Falling Edge Address Hold Time

Models: MSM83C154S MSM80C154S

1 36
Download 36 pages 7.51 Kb
Page 29
Image 29

¡ Semiconductor

MSM80C154S/83C154S

AC Characteristics

(1) External program memory access AC characteristics

VCC=2.2 to 6.0V, VSS=0V, Ta=–40°C to +85°C

PORT 0, ALE, and PSEN connected with 100pF load, other connected with 80pF load

 

 

Variable clock from*1

 

Parameter

Symble

 

1 to 24 MHz

Unit

 

 

 

 

 

 

 

 

Min.

 

Max.

 

 

 

 

 

 

 

XTAL1, XTAL 2 Oscillation Cycle

tCLCL

41.7

 

1000

ns

ALE Signal Width

tLHLL

2tCLCL-40

 

ns

Address Setup Time

tAVLL

1tCLCL-15

 

ns

(to ALE Falling Edge)

 

 

 

 

 

 

 

 

 

 

 

 

Address Hold Time

tLLAX

1tCLCL-35

 

ns

(from ALE Falling Edge)

 

 

 

 

 

 

 

 

 

 

 

 

Instruction Data Read Time

tLLPL

 

4tCLCL-100

ns

(from ALE Falling Edge)

 

 

 

 

 

 

 

 

 

 

 

 

From ALE Falling Edge to PSEN

tLLPL

1tCLCL-30

 

ns

Falling Edge

 

 

 

 

 

 

 

 

 

 

 

 

PSEN Signal Width

tPLPH

3tCLCL-35

 

ns

Instruction Data Read Time

tPLIV

 

3tCLCL-45

ns

(from PSEN Falling Edge)

 

 

 

 

 

 

 

 

 

 

 

 

Instruction Data Hold Time

tPXIX

0

 

ns

(from PSEN Rising Edge)

 

 

 

 

 

 

 

 

 

 

 

 

Bus Floating Time after Instruction

tPXIZ

 

1tCLCL-20

ns

Data Read (from PSEN Rising Edge)

 

 

 

 

 

 

 

 

 

 

 

 

Instruction Data Read Time

tAVIV

 

5tCLCL-105

ns

(from Address Output)

 

 

 

 

 

 

 

 

 

 

 

 

Bus Floating Time(PSEN Rising

tAZPL

0

 

ns

Edge from Address float)

 

 

 

 

 

 

 

 

 

 

 

 

Address Output Time from PSEN

tPXAV

1tCLCL-20

 

ns

Rising Edge

 

 

 

 

 

 

 

 

 

 

 

 

*1 The variable check is from 0 to 24 MHz when the external check is used.

287

Page 29
Image 29
Oki MSM83C154S manual ALE Signal Width, Address Setup Time, To ALE Falling Edge Address Hold Time, From ALE Falling Edge