Using the Variable Control Voice Actuator (VCVA)

 

Press the REC button to start recording.

 

When the sound volume is lower than the

7

7 preset threshold sound level, recording

automatically stops after 1 sec approximately,

recording automatically pauses after approximately 1 second, and “STANDBY” flashes on the display. The record/play indicator lamp glows when recording starts and flashes when recording pauses.

* When the remote controller is connected, the REC indicator lamp on the remote controller lights up but the record/play indicator lamp on the recorder will be switched off.

Control V oice Actuator (VCVA)

Adjust the start/stop actuation level

Press the FF or REW button to adjust the Using the Variable Control Voice Actuator (VCVA)7 pause sound level during recording.

The VCVA level can be set to any of 15 different values. The higher the value, the more sensitive the recoder to sounds. At the highest value, even the faintest sound will activate recording.

The VCVA pause sound level can be adjusted according to the ambient (background) noise.

aLevel meter (varies according to the sound volume being recorded)

bStart level (moves to the right/left according to the set level)

aPress the REC button to start recording.Control V oice Actuator (VCVA)Adjust the start/stop actuation levelaLevel meter (varies according to the sound volume being recorded)bStart level (moves to the right/left according to the set level)Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background bManual background

................................................................................................................

Notes

The start/stop actuation level also varies depending on the selected microphone sensitivity mode (P.28).