Water Leakage Test

The final test after loading the camera is explained below. Always perform this test. It can be performed easily in a water tank or a bathtub. The required time is about five minutes.

 

 

Simple water leakage test

Explanatory image

Hints

 

 

 

 

 

 

 

1 Place the Case slowly into

 

As the rear lid of the Case is transparent,

 

 

 

waterdrops entering into it can be confirmed

 

 

the water.

 

 

 

 

easily.

 

 

 

 

 

 

 

 

 

 

 

2 At first, immerse the Case

 

In case of trouble with the O-ring, three

 

 

 

seconds is enough for water to enter. Are there

 

 

for only three seconds.

 

 

 

 

air bubbles coming out between the lids?

 

 

 

 

 

 

 

 

 

 

 

3 Check that no water has

 

Remove the Case from the water and check

 

 

 

that no water has leaked at the inside of the

 

 

entered the Case.

 

 

 

 

Case.

 

 

 

 

 

 

 

 

 

 

 

4 Next, immerse the Case for

 

Check carefully for air bubbles!

 

 

 

Do not perform any operation yet, but just

 

 

30 seconds.

 

 

 

 

observe.

 

 

 

 

 

 

 

 

 

 

 

5 Check that no water has

 

Remove the Case from the water and check

 

 

 

that no water has leaked at the bottom of the

 

 

entered the Case.

 

 

 

 

Case.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

En

 

6 Next, check by immersing

 

Check carefully for air bubbles!

 

 

 

Try operation of the buttons used frequently.

 

 

for three minutes.

 

Check carefully for air bubbles!

 

 

 

 

 

 

 

 

 

 

 

7 This is the final check. Has

 

Has the silica gel become moist?

 

 

the silica gel become moist?

 

Please check carefully!

 

 

 

 

 

 

 

8 If there is no water leakage

 

 

 

 

and everything is functioning

 

Now everything is all right!

 

 

correctly, you are ready to

 

 

 

 

 

 

 

start shooting underwater.

 

 

 

 

 

 

 

EN 19