Omega Engineering CN9400 F u n c t i o n L i s t, LEVEL 3 continued, Reu.L, Span, Zero, Chek

Models: CN9400

1 38
Download 38 pages 50.17 Kb
Page 24
Image 24
LEVEL 3 (continued)

F u n c t i o n L i s t

LEVEL 3 (continued)

Function

Options

[Factory settings] shown in brackets

REU.L

Select SP1/2 LED indicator modes

 

 

 

SP1

SP2

 

[1n.2n]

Normal

Normal

 

1i.2n

Invert

Normal

 

1n.2i

Normal

Invert

 

1i.2i

Invert

Invert

SPAN

[0.0]

to ±25% sensor maximum

 

 

Sensor span adjust

 

 

For recalibrating to a remote standard e.g. External

 

Meter, data logger. See ADVANCED SETTINGS page

 

24,25.

 

 

ZERO

[0.0]

to ±25% sensor f/s

 

 

Zero sensor error, see SPAn

 

CHEK

[oFF]

on

 

 

Select control accuracy monitor

 

READ

[Var]

hi Lo

 

 

Read control accuracy monitor

 

Function

TECH

VER

RSET

Options [Factory settings] shown in brackets

[Ct A] CT b Ct 1 Ct 2 Ct 3

Ct 4 oS 1 uS oS 2

Read Autotune tuning cycle data (see figure, page 14)
Software version number

[nonE] ALL

Resets all functions to factory settings

Caution: Note current configuration before using this function, otherwise initial configuration and OEM settings must be re-entered.

20

Page 24
Image 24
Omega Engineering CN9400 F u n c t i o n L i s t, LEVEL 3 continued, Reu.L, Span, Zero, Chek, Read, Normal, Invert, 24,25