LEVEL 4
Access to level 4 is gained through | VER in level 3. |
Press and hold ▲ and ▼ |
|
for 10 seconds. |
|
Enter level 4 at Lock, release ▲ and ▼ together. |
Display reads | LOCK |
| |
| NONE |
Program security using Lock
Select from three Lock options:
Press and hold ✱, press ▲ to index.
LEV.3 locks level 3 and 4 only- Technical Functions.
LEV.2 locks levels 2, 3 and 4 only - Configuration and Technical Functions.
ALL | locks all functions | LOCK |
|
| ALL |
Note: | Locked functions and options may be read. |
|
Function | Options [Factory settings] shown in brackets |
Press ▼ to access following functions
PROG [Auto] StAY
Program mode
NO.AL [oFF] on
Disable SP2 alarm annunciator
Select on to disable
DIS.S dir 1 to 32 [6]
Display sensitivity
dir = direct display of input
1= maximum, 32 = minimum sensitivity
DER.S 0.1 to 1.0 [0.5]
Derivative sensitivity