4.12.1 Remote iServer

It’s recommended to configure the Remote iServer and have it up and running before the Local iServer is configured.

1.A static IP address must be assigned to the Remote iServer. This means that the DHCP must remain disabled. Refer to the DHCP section of the user’s manual for details.

2.Use a browser to access the Remote iServer’s WEB page. Simply type the iServer’s IP address at the browser’s URL location (i.e. 192.168.1.50) followed by an Enter key. You should then see the iServer’s main WEB page.

3.Click on the Update button.

4.Click on Configuration, you will be prompted with a Password (default is 12345678).

5.On the Configuration page, under Serial Communication section, make sure the parameters such as Baud Rate, Data Bits, Parity, Stop Bits, Flow Control, etc. match with your attached serial device.

6.Make sure to set the End Character (Hex) to 0D and the Timeout to 500.

7.Under Terminal Server section, set Number of Connections to 1 or higher.

8.Click on Save button for the changes to take place.

Make sure that the serial cable and communication settings between the iServer and the serial device are valid.

Figure 4.21

shows the valid values that need to be set

in the Remote iServer. The Baud Rate, Data Bits, Parity, Stop Bits, Flow Control, and Transceiver values depend on what the serial device supports.

CONFIGURATION

Address http://192.168.1.50

CONFIGURATION

Serial Communication

Baud Rate 9600

 

Data Bit 7 Bits

Parity odd

Stop Bits1 bit

Flow Control none

Transciever RS-485

Modbus/TCP disable

End Character (Hex)

0D

Forward End Char enable

Timeout 0500 msecs

 

Serial Port Password

disable

1234abcd

 

 

 

Terminal Server

TCP/UDP TCP

Server Type slave

Number of Connections 1 Local Port 02000

Connection Ctrl

not used

 

Device No. 1

Connection Timeout 00100 msecs

 

Remote Access (Tunneling)

Remote Access

disable

Remote IP Address 0.0.0.0

Remote Port 02000

 

 

 

 

Save

Reset

 

 

 

 

 

Main Menu

 

Figure 4.21 Configuration Menu - Remote iServer