Omega Vehicle Security FPU500 manual Problem, Solution, Motor will not turn

Models: FPU500

1 52
Download 52 pages 51.95 Kb
Page 37
Image 37
Motor will not turn

 

 

 

Troubleshooting Guide

7

 

 

 

 

 

 

 

 

 

 

 

 

 

Problem

 

Solution

 

 

 

Motor will not turn

1.

Make sure the tubing is loaded

 

 

 

 

 

properly. The tubing should be

 

 

 

 

 

centered in the middle of the rollers.

 

 

 

Reload if necessary.

 

 

 

 

2.

Check to see if the motor is turned

 

 

 

 

 

on.

 

 

 

 

3.

Check motor fuse.

 

 

 

 

 

 

 

 

Motor will not turn – overcurrent condition

1.Make sure the tubing is loaded properly. The tubing should be centered in the middle of the rollers.

2.Make sure the tubing wall thickness is correct (refer to Table 9-1).

3.The tubing durometer may be too high for the pump (refer to Chapter 9).

4.The tubing may be caught on the bottom roller. Reposition the roller slightly and load the tubing again.

The pump will not stay on the motor

1.The pump is not properly mounted to the motor. Refer to Section 3.

2.The mounting screws are loose. Tighten the screws, if necessary.

7-3

Page 37
Image 37
Omega Vehicle Security FPU500 manual Problem, Solution, Motor will not turn