Specifications

Table 9-1. Tubing Size vs Min. Motor Speed Required for Priming *

Tubing Size - ID

Minimum Motor Speed (RPM)

132"

300

116"

250

18"

100

316"

50

14"

50

516"

50

1mm

300

 

 

2mm

250

 

 

3mm

100

 

 

4mm

50

 

 

5mm

50

 

 

6mm

50

 

 

7mm

50

 

 

8mm

50

 

 

(* Tests are done using 20°C water, 0 PSI back pressure)

Maximum Fluid Back Pressure:

20 PSI

Tube Wall Thickness Required:

116" (1.5 mm)

Tube Inner Diameter Range:

132" to 516"

 

(1 mm to 8 mm)

Tubing Materials:

Vinyl, Viton, Tygon,

 

Silicone, Santoprene,

 

and Norprene

Tubing Durometer:

68 or less

Fluid Temperature Range:

-50°F to 300°F

 

(-46°C to 149°C)