Omega Vehicle Security FPU500 manual Metric mL per Revolution numbers are rounded off

Models: FPU500

1 52
Download 52 pages 51.95 Kb
Page 43
Image 43
* Metric mL per Revolution numbers are rounded off

Specifications 9

 

Table 9-2. Average Flow Rates (Cont’d)

 

 

 

 

 

 

Tubing Wall

Tubing Size

mL per

Minimum Flow

Maximum Flow

Thickness

Inner Diameter

Revolution

Rate at 600 RPM

Rate at 600 RPM

 

 

 

(mL/Minute)

(mL/Minute)

1.5 mm

3.0 mm

0.8*

8

482

1.5 mm

4.0 mm

1.43*

15

857

1.5 mm

5.0 mm

2.1*

21

1257

1.5 mm

6.0 mm

2.7*

27

1607

1.5 mm

7.0 mm

3.6*

37

2187

1.5 mm

8.0 mm

3.9*

39

2316

* Metric mL per Revolution numbers are rounded off

Normalized flow rates (mL per revolution) vary significantly, based on motor speed, tubing materials, and mechanical tolerances in pump dimensions. In addition, the variances are different for the different tubing dimensions. Variances from the normalized flow rates of Table 9-2 are shown below. The data is shown for new tubing only.

Tubing operating life tests are done at 600 RPM, with 20°C water, 0 PSI back pressure until the tubing breaks

Table 9-3. Variances in Normalized Flow Rate (mL per Revolution)

Tubing Size

Due to

Between Pumps

Due to Different

Inner Diameter

Motor

(due to Mechanical

Tubing Materials

(in.)

Speed

Tolerances)

 

 

 

 

 

132

±10%

±25%

±20%

116

±10%

±15%

±15%

18

±10%

±10%

±5%

316

±5%

±10%

±5%

14

±5%

±15%

±5%

516

±15%

±20%

±10%

9-3

Page 43
Image 43