Section 3 Setting the Sensor Controller to Obtain Sensing Information from

Setting Logic Operation Methods

Set how logic operations are to be performed on the tasks and CH specified by the assignment settings.

▲FUNMODE-[SENSING]-[CALC]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting

 

 

Description

OFF

 

Expressions are not set.

 

 

 

 

 

 

 

 

 

 

 

 

 

CH

 

Logic operations are not performed, and the measured value of a specific CH

 

 

is input as it is.Select the target CH.

 

 

 

 

 

 

 

 

 

 

 

 

 

CALC

THICK

Select this item to set the sandwiched thickness. (sandwiched measurement)

 

K-(X+Y)

• Xrange: input A to input I, TASK1 to TASK4

 

 

• Yrange: input A to input I, TASK1 to TASK4

 

 

• The thickness input is automatically set.

 

 

 

 

 

During thickness input, the mode changes to the measurement

 

 

mode, and the current thickness value is displayed on the main dis-

 

 

play. For this reason, during thickness input enter in a measurement

 

 

ready state.

 

 

 

 

 

 

 

 

 

K

 

 

 

 

 

 

 

X

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STEP

Select this item to set step measurement. (step measurement)

X-Y

• Xrange: input A to input I, TASK1 to TASK4

 

 

 

 

• Yrange: input A to input I, TASK1 to TASK4

 

 

 

 

 

 

Y

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K+mX+nY

Select this to perform logic operations on X and Y with the coefficient freely

 

set.

 

 

 

K range: -999999 to 999999

m range: -10.0 to 10.0

n range: -10.0 to 10.0

Xrange: input A to input I, TASK1 to TASK4

Yrange: input A to input I, TASK1 to TASK4

AVE

Select this item to average the values of input A to input I, and the values of

(average height

TASK1 to TASK4.

measurement)

Set ON/OFF to each input and each TASK.The average of inputs set to ON

 

and TASK is calculated.

 

 

MAX-MIN

Select this item to subtract the maximum and minimum values by the values

(flatness mea-

of input A to input I.

surement)

Set ON/OFF to each input and each TASK.The average of inputs set to ON

 

and TASK is calculated.

Inputs do not undergo logical operation when “None” is set. Example: The operation “-B” is performed when “None” is set to input A, “3CH” is assigned to input B and A-B is selected.

Section 3 SETUP

ZS-MDC

User’s Manual

3-15

Page 53
Image 53
Omron ZS-MDC user manual Setting Logic Operation Methods

ZS-MDC specifications

The Omron ZS-MDC is a sophisticated multi-functional device designed to enhance the efficiency and reliability of industrial automation systems. Equipped with a variety of features, this device caters to various applications including packaging, assembly, and material handling. Its versatility and advanced technology make it an ideal choice for industries seeking to optimize their operations.

One of the main features of the Omron ZS-MDC is its comprehensive sensor integration capability. The device can accommodate multiple sensors and actuators, allowing for flexible configurations tailored to specific applications. This modularity ensures that manufacturers can adapt the device to meet their unique requirements while maintaining high performance.

Another significant feature is the built-in communication interfaces. The ZS-MDC supports various communication protocols like EtherCAT, PROFINET, and Ethernet/IP, which makes it highly compatible with existing automation systems. This ability to seamlessly connect enhances overall system performance and facilitates real-time data exchange, allowing for improved monitoring, control, and diagnostics.

The device is also characterized by its robust design, built to withstand challenging industrial environments. With an IP67 rating, the ZS-MDC is resistant to dust and water, making it suitable for harsh conditions where exposure to contaminants is a concern. Additionally, its durable construction ensures longevity and reduces the need for frequent maintenance, translating to cost savings for manufacturers.

Technologically, the Omron ZS-MDC incorporates advanced processing capabilities enabling it to handle complex tasks with ease. It features high-speed processing and data handling, reducing response times in critical applications. This performance is further enhanced by the integration of intelligent algorithms that enable predictive maintenance and failure detection, ultimately leading to minimized downtime.

User-friendliness is another key characteristic of the ZS-MDC. The device is designed with an intuitive user interface that simplifies configuration and monitoring, thereby reducing the time and expertise required for setup. Moreover, it supports remote access functionality, allowing operators to manage and troubleshoot the device from anywhere, which boosts overall operational efficiency.

In summary, the Omron ZS-MDC stands out with its versatile sensor integration, robust communication capabilities, durable design, advanced processing, and user-friendly interface. These features make it a valuable asset in the realm of industrial automation, helping businesses drive productivity and enhance operational reliability.