Optibase MGW 2400 WMT user manual To edit the default IP address at a later stage

Models: MGW 2400 WMT

1 156
Download 156 pages 35.3 Kb
Page 61
Image 61

Chapter 3 • Installing Software

To edit the default IP address at a later stage:

1.Make sure that you close the MGW 2400 EMS.

2.Browse the MGW 2400 EMS folders for EMSConfig.ini and create a backup. Save the backup in a different folder on your PC.

3.Open EMSConfi.ini; the first line reads for example ems2400.snmp.deviceIP 172.16.100.137.

4.Change the registered IP address to the desired IP address.

5.Save and close EMSConfig.ini; the MGW 2400 EMS displays the new IP address once the MGW 2400 EMS Logon window appears.

Note

Make sure that only one NIC is enabled on the Management PC, otherwise the MGW 2400 EMS cannot communicate properly with MGW 2400.

To install a new version of MGW 2400 EMS at a later stage, first uninstall the current version of MGW 2400 EMS.

If the available disk space is insufficient, installing MGW 2400 EMS will fail.

If you want to uninstall the MGW 2400 EMS after you edited EMSConfig.ini, you will have to manually delete the MGW 2400 folder.